Water Cooled Glycol Chiller is an effective industrial cooling device that handles long-term processes that must operate at constant and low temperatures. The chillers use a water and glycol mixture to provide stable cooling close to 0°C without freezing or damaging the system. The screw compressor has a continuous operation and smooth operation, which makes it very suitable in heavy-duty and high-capacity operations.
Water-cooled chillers use a cooling tower to release the heat rather than air-cooled systems, which makes them more energy efficient and able to maintain a steady temperature, particularly in hot ambient environments. These systems find extensive applications in pharmaceutical, food processing, brewery and chemical plants as well as plastic manufacturing plants.
Being a reliable Water Cooled Glycol Chiller Manufacturers in Pune, we design the systems that will fit heavy plant conditions in terms of maintenance. We are also reliable Water Cooled Glycol Screw Chiller Exporters in Pune, reliable chillers that can be supplied at different voltages and frequencies, at the standards of varying standards of operations globally.
Water cooled Glycol Chillers in Pune offer precise and lower temperature cooling. The chilling system utilizes a water and glycol solution which, acting as an antifreeze, provides increased cooling efficiency. Chillers operate a water circuit to remove refrigerant heat via a condenser, which is cooled by a cooling tower or heat exchanger.
We made chillers that are not only efficient but also reliable because in ma industries need chillers that are used in over long hours of continuous operation. Our chillers are commonly used in many industries where stable temperatures is issue, such as pharmaceutical production, food processing, beverage cooling, and chemical manufacturing.
We are a leading Water Cooled Glycol Chiller Manufacturers in Pune who expertly made Best chillers in Pune that meet local and international standards. We focus on high manufacturing efficiency and reliability.
Glycol chillers are water cooled chillers that have simple but effective principles. Process water blended with glycol flows through the evaporator. It soaks up the heat from the industrial equipment. Then heat is transferred to the refrigerant chillers.
The refrigerant that contains heat is transferred to the water cooled condenser. Here the cooling water soaks up the heat from the refrigerant and carries it to a cooling tower where it is discharged to the environment. The process is repeated and the water and glycol blend is returned to the process to maintain low temperatures.
Chillers perform consistently and even more optimally under large loads and even high ambient temperatures cooling water blended with glycol performs more effectively than air. For that reason and especially when cooling performance is unstable these chillers are best.
Aquatechplus is an reliable Water Cooled Glycol Chiller Supplier in {locations}, With our years of experience we have gained a reputation for delivering chillers in {locations} for your needs. With our extensive industry knowledge, our team is able to provide and manage the delivery, installation and commissioning of the correct chiller for your operation.
We have built a reputation for working with each customer to understand the site, as well as the flow, and the temperature range requirements. We strive to offer tailored solutions that are energy efficient and durable.
- Food Industries : - Dairy, bottling, food processing, and several other cooling operations in food and beverage
- Laboratories and Pharmaceuticals: exact low-temperature regulation for delicate processes
- Chemical Processing: cooling mixers, and other heat-producing apparatuses, and reactors
- Plastic and Polymer Industry: cooling molds and machines for consistent quality of production
- HVAC Systems: cooling for large commercial and industrial buildings
- Cold Storage and Warehousing: keeping controlled temperature environments for perishables
Aquatech plus water cooled glycol chillers are built for efficiency and reliability. They are able to achieve ±1°C of variation from the set temperature for the most precise temperature control. This is critically needed for sensitive applications and processes. The glycol-water mixture provides freeze protection for the heat exchanger and built-in protection to control the system's corrosion and scaling.
Chillers consume less energy due to the optimized design of the water circuit and the EC (electronic commutated) compressors. The design incorporates durability seen in shell-and-tube evaporators, mild steel or stainless steel casings, and water pumps constructed from premium alloy. Maintenance is designed to be simple, and the system design provides fast access for features and the overall system is designed for a long life with minimal downtime.
A typical Water Cooled Glycol Chiller contains semi-hermetic screw compressor or VFD screw compressor for even further energy efficient operation. Water-cooled condensers provide the best heat rejection, and shell-and-tube evaporators are most common for glycol-water applications.
A glycol tank and a circulation pump are included to control the temperature and flow of the glycol. Additionally, PLC controls with digital screens for monitoring, safety, and diagnostics are included. For operational consistency and safety, high efficiency fans, safety valves, and sensors are integrated.
We have wide network of Water Cooled Glycol Chiller Dealers in Pune. Our each dealer is carefully trained because they are not only sell chillers but also provide complete technical guidance. This guidance helps you to choose the right capacity for your specific industrial needs.
They help you with the first setup of the machine, so you don't have to worry about how to setup it on work-day. Our dealers guide you even after buying from our product. They will assist for such topics like :- maintenance, troubleshooting, how to get spare parts, and more. This means you don't just get a machine, you get a valuable cooling system that helps keeps processes working smoothly and reliably.
Cooling capacity and temperature range
Glycol chillers are versatile for various cooling loads. Smaller units are suitable for use in laboratories or food processing. Larger units drive industrial plants and chemical processes or are used in HVAC Systems. They can sustain temperatures of +20°C to -10°C and can go even lower with customized glycol blends.
Large units majorly contain multiple compressor circuits for redundancy. This ensures that the chiller continues operating even if one section fails or needs servicing. This is critical in pharma or critical manufacturing.
Glycol chillers handle a variety of cooling loads. Smaller units can be used in laboratories and food processing. Larger units are used for industrial plants, chemical processes, or big HVAC systems. They are both reliable and versatile with temperature control between +20°C to -10°C (deeper with custom glycol blends).
High-capacity units typically come with multiple compressor circuits for redundancy. This guarantees the system continues to run, even if one section needs maintenance. This is particularly beneficial for pharmaceutical or other critical manufacturing.
Maintenance is the major key of every machines and Water-cooled glycol chillers need maintenance of compressor, evaporator, and condenser. To avoid freezing, check glycol concentration. A working water flow and clear condenser are needed for optimal efficiency.
Controls and Sensors should be monitored regularly and alarms and deviations corrected as needed. To avoid cavitation or pressure drops, service on the pumps and valves is needed. To help maintain optimal performance over the system’s lifetime, Aquatech plus provides detailed service guides and training.
Aquatech plus is among reliable Water Cooled Glycol Chiller Exporters in Pune. Our each chillers are tested before dispatching and follow all global quality standards for reliability.
We design our export chillers to operate seamlessly in any environment, Europe, or the Middle East. Our export team has the logistics and documentation covered, customizing to site specifications to make the process efficient for international clients. When working with Aquatech plus, you have a partner for global cooling solutions where all aspects of a product are guaranteed to be of the highest quality.
Our technical staff will obtain knowledge about your procedures, propose the most suitable solution, and assist you during the installation and commissioning phases.
| Item | Parameter | Temp | Unit | FCL-3WL | FCL-5WL | FCL-6WL | FCL-8WL | FCL-10WL | FCL-12WL | FCL-15WL | FCL-20WL | FCL-25WL | FCL-30WL | FCL-40WL |
|---|---|---|---|---|---|---|---|---|---|---|---|---|---|---|
| Cooling Capacity (kW – 50Hz / 60Hz) | ||||||||||||||
| Cooling Capacity | -10°C | kW | 4.5 / 5.4 | 7.7 / 9.3 | 9.1 / 11 | 11.7 / 14.1 | 16.1 / 19.3 | 19.1 / 22.9 | 23.3 / 28 | 32.2 / 38.6 | 38.2 / 45.8 | 46.6 / 56 | 62.5 / 75 | |
| -20°C | kW | 2.7 / 3.24 | 4.1 / 4.92 | 5.3 / 6.24 | 8.1 / 9.72 | 9.8 / 11.76 | 10.6 / 12.72 | 13.6 / 16.32 | 20.4 / 24.48 | 25 / 28.8 | 29.4 / 35.28 | 38.5 / 46.2 | ||
| -30°C | kW | 1.31 / 1.57 | 2.1 / 2.52 | 2.8 / 3.36 | 4.3 / 5.36 | 4.9 / 5.88 | 5.6 / 6.72 | 7.9 / 9.48 | 11.2 / 13.44 | 13.7 / 16.44 | 16.1 / 19.32 | 21.2 / 25.44 | ||
| Condenser (Shell & Tube) | ||||||||||||||
| Cooling Water | -10°C | m³/h | 1.0 / 1.21 | 1.7 / 2.06 | 2.03 / 2.44 | 2.62 / 3.14 | 3.6 / 4.32 | 4.27 / 5.12 | 5.2 / 6.24 | 7.23 / 8.67 | 8.54 / 10.25 | 10.4 / 12.5 | 14 / 16.8 | |
| Outlet Pipe | inch | 1½" | 1½" | 1½" | 1½" | 1½" | 1½" | 2" | 2" | 2½" | 3" | 3" | ||
| Evaporator | ||||||||||||||
| Chilled Water | -10°C | m³/h | 0.77 / 0.93 | 1.33 / 1.59 | 1.56 / 1.88 | 2.01 / 1.73 | 2.77 / 3.32 | 3.28 / 3.94 | 4.0 / 4.8 | 5.56 / 6.65 | 6.57 / 7.89 | 8.1 / 9.62 | 10.75 / 12.3 | |
| Inlet / Outlet | inch | 1" | 1" | 1" | 1" | 1½" | 1½" | 2" | 2" | 2½" | 2½" | 3" | ||
| Electrical & Mechanical | ||||||||||||||
| Input Power | kW | 3 | 4.5 | 5.25 | 6.75 | 8.6 | 10.1 | 12.8 | 14.56 | 21 | 26.5 | 34 | ||
| Max Current | A | 7.5 | 11 | 13 | 16.5 | 21 | 25 | 31 | 42 | 51 | 64 | 83 | ||
| Power Source | 3PH~380V / 415V / 480V ~ 50Hz / 60Hz (3PH~200V / 220V) | |||||||||||||
| Refrigerant | Type | R22 (R404A / R507) | ||||||||||||
| Compressor | Type | Hermetic Scroll (Piston) | ||||||||||||
| Dimensions & Weight | ||||||||||||||
| Length | mm | 910 | 910 | 910 | 1250 | 1250 | 1250 | 1600 | 1600 | 1950 | 1950 | 2000 | ||
| Width | mm | 480 | 480 | 480 | 680 | 680 | 680 | 750 | 750 | 850 | 850 | 980 | ||
| Height | mm | 1000 | 1000 | 1000 | 1380 | 1380 | 1380 | 1600 | 1600 | 1700 | 1700 | 1700 | ||
| Net Weight | kg | 130 | 150 | 180 | 230 | 260 | 330 | 420 | 460 | 680 | 720 | 870 | ||
At low or sub-zero temperatures, the system is frozen with the help of glycol. It prevents ice formation and thermal damages of heat exchangers, pipes and pumps.
Water-cooled glycol chillers are indicated when the cooling load is large and inelastic. They give improved efficiency and consistency during processes at low temperatures in industries.
Depending on the concentration of the glycol and the design of the system, the temperature of the standard chilled water can be dropped to as low as -30°C or below. They are applicable in selective and high-demand low temperatures.
An increase in glycol concentration increases the freeze protection and decreases the heat transfer efficiency. Appropriate choice strikes the right balance between low-temperature performance and optimum energy performance.
This needs a cooling tower, a condenser water pump and a decent water treatment system. These elements guarantee effective rejection of heat as well as durability.
They find application in pharmaceuticals, chemical processing, food and beverage and speciality manufacturing. These industries need constant cooling that is at low or below-zero temperatures.
We carry a specified warranty and effective after sales services to all goods provided by us. Our warranty and service system will be aimed at long-term performance, reliability in terms of work, and peace of mind of our clients, both domestic and international.
Every product has a standard warranty of manufacturing defects dating back to the dispatch date or the date of installation, as existing. The warranty includes the defects to the quality of material and workmanship in the normal operation condition.
There are various warranty terms based on the product category, model, application and environment of use. Specifics on warranty period and coverage are provided in detail during the confirmation of orders or issue of invoice.
Warranty is not applicable on damages caused by:
Our technical support provides our clients with instructions on how to install, answer technical questions as well as basic troubleshooting. Depending on where the project is located, support is accomplished by providing documentation, remote assistance or by organizing services with service partners.
We assist both domestic and foreign clients with well-organized contact and export documentation. In the case of international customers, technical support and service management are offered remotely to have a comfortable functioning and prompt problem resolution.
There is a process in which service requests are processed. When we get a support request, we examine the problem and determine the warranty eligibility and suggest a remedy. The response timelines can be different depending on the product, location and availability of the components.
The above warranty and support terms are the standard policy which we use in our whole product line. Particular product-level warranty information might vary and are provided independently when taking orders.
This Warranty & Support section represents our standard company-wide policy and is consistently applied across our complete product range. The content is intentionally displayed on multiple product pages to communicate uniform warranty coverage, service terms, and support procedures.
While the core policy remains the same, actual warranty duration, coverage scope, and service conditions may vary by product model, application, and operating environment. Product-specific warranty details are shared separately at the time of order confirmation or documentation.