Air Cooled Chillers are adopted widely in industries and businesses that have to rely on reliable and energy-efficient cooling without water-intensive cooling towers. These systems were designed to run on the ambient air and can be used in HVAC applications, manufacturing facilities and hospitals. As leading Air Cooled Chillers Manufacturers in Hyderabad, we are interested in providing stable performance, low operating power and long service life even in extreme operating conditions.
The chillers operate on a vapour compression refrigeration cycle and thus they maintain accurate temperature regulation at low downtimes and low maintenance costs. Air-cooled chillers have both standard and customised configurations with small to heavy-duty industrial loads. The most popular Air Cooled Chillers Exporters in Hyderabad are also suppliers of export-quality chillers that meet global standards of quality and safety in the market, and as such, chillers have been popular in the world market as efficient, cost-saving and sustainable cooling units.
Trusted Air Cooled Chiller Manufacturers in Hyderabad provide high-performance, advanced cooling systems that are designed with long service life, low power consumption, and reliable performance. Industrial and commercial applications that demand stable cooling, minimal downtime, and regulated operating costs utilize Aquatech Plus's superior air-cooled chiller systems.
The industries that our engineering team serves include HVAC, manufacturing, dairy, food processing, and data centers, and each system designed by our engineering team, depending on the real operating conditions, is Air Cooled Chillers in Hyderabad. With its modern manufacturing factories, well-trained engineers, and stringent quality assurance, Aquatechplus has gained a favorable reputation throughout the state of Hyderabad. The performance of each chiller is stable, maintenance-free, and has a long service life.
Aquatech Plus is a reliable air-cooled chiller supplier in Hyderabad because the company supplies quality and timely units of the chillers to industrial plants and commercial buildings, as well as OEMs. All air-cooled chillers are performance tested before shipment to guarantee durability and performance.
The efficient supply chain and clear pricing will enable our customers to get the appropriate solution at a competitive price without delays and the sacrifice of quality.
An Air Cooled Chiller is a cooling method that removes heat from water or process fluid with the help of air that is ambient air. Machines or heat exchangers are used to pump the chilled fluid to keep it at the required temperature.
In Aquatech Plus, our chiller are run on a vapor-compression-based refrigeration cycle that entails evaporation, compression, condensation, and expansion. To understand this further, the Air Cooled Chiller Working Principle is how the heat is taken in the evaporator and expelled into the atmosphere by use of condenser fans. We also have technical sources, like an Air Cooled Chiller Diagram, to enable the clients to know about the system layout and flow.
We design our cooling systems to function continuously in harsh conditions, ensuring their reliability and efficiency over time.
Since Aquatech Plus specialises in cooling systems, we have earned a reputation as one of the dependable Air Cooled Chiller Exporters in Hyderabad. We tailor our products for international markets. We manufacture all our chiller in compliance with CE and RoHS standards to guarantee safety, efficiency, and environmental responsibility. Export-grade packaging and documentation facilitate our overseas deliveries.
There are several variations of Air Cooled Chiller available at Aquatech Plus in accordance with various cooling needs:
Our chiller come with a capacity of 1 TR to 20 TR, with designs being customized on order. The refrigerants that have been supported are R410A, R407C, R134a, R404A, R22, R32, and R513A, so that they operate efficiently and comply with the regulations. The Air Cooled Chiller Diagram falls under the category of technical documentation that can be used during installation and maintenance.
We use our Air Cooled Chiller systems in:
Maintaining precise temperature control enhances productivity, protects equipment, and reduces downtime.
|
Category |
Details/Specifications |
|
Chiller Type |
Air cooled chiller systems are designed for efficient heat rejection using ambient air |
|
Cooling Capacity Range |
1 TR to 20 TR – suitable for commercial and industrial applications |
|
Supported Refrigerants |
R410A, R407C, R134a, R404A, R22, R32, R513A |
|
Condenser Type |
Air-cooled condenser with axial fans for low maintenance |
|
Compressor Options |
Scroll, Screw, Reciprocating – Semi-Hermetic, Hermetic & Open Type |
|
Core Function |
Removes heat from the process fluid and maintains a consistent temperature |
|
Key Components |
Evaporator, Compressor, Air-Cooled Condenser, Expansion Valve |
|
Operating Advantage |
No cooling tower required, low water consumption |
|
Installation |
Easy outdoor installation with minimal civil work |
Aquatech Plus is listed among reputable Air Cooled Chiller Dealers in Hyderabad, and it provides professional help in choosing the capacity and configuration. Services such as analysis of applications, technical support, and installations have been offered, as well as after-sales support from our dealers to ensure that the system operates smoothly.
Aquatech Plus provides full-service Air Cooled Chiller project solutions, including planning of the system right up to the eventual commissioning of the system. Our combined strategy simplifies the project and provides an effortless implementation and reliable cooling performance with only one reliable partner.
This inclusive implementation model assists clients in saving time, lessening the coordination work, and attaining effective and long-term cooling solutions.
Serving Industrial Hubs in Hyderabad
Aquatech Plus is based in Gujarat, India, and it provides Air Cooled Chiller systems in key industrial belts in and around Hyderabad, including HITEC City, Gachibowli, Jeedimetla. Our well-developed logistics system guarantees an on-time delivery and a reliable technical service.
Shopping to get a good Air Cooled Chiller? Call Aquatech Plus and talk about your needs and get a unique, effective, and sustainable cooling solution.
| Air Cooled Chillers Technical Specifications | |||||||
|---|---|---|---|---|---|---|---|
| Model | FMACA 9 | FMACA 12 | FMACA 18 | FMACA 22 | FMACA 24 | FMACA 28 |
|---|---|---|---|---|---|---|
| Nominal Cooling Capacity kW (TR) | 33.2 (9.4) | 43 (12.6) | 66.4 (18.8) | 78.78 (22.4) | 86 (24.4) | 100.3 (28.5) |
| At Air Outlet Temperature °C | 15 | |||||
| Design Air Flow Rate m³/hr | 2000 | 3000 | 4000 | 5000 | 5500 | 7000 |
| Ambient Temperature °C | 40 | |||||
| Control Range °C | Pluse (+) 5 up to Plus (+) 20 | |||||
| Cooling Circuit | ||||||
| Cooling Agent | R22 | |||||
| No. of Compressor | 2 | |||||
| No. of Gas Circuit | 1 | |||||
| No. of Fan / Fan Power | 1 / 2.63 | 2 / 2.63 | 2 / 2.33 | |||
| Compressor Power (kW) | 5.45 x 2 | 6.32 x 2 | 8.9 x 2 | 10.82 x 2 | 11.6 x 2 | 13.65 x 2 |
| Process Air Data | ||||||
| Maximum Air Flow Rate m³/hr | 2000 | 3000 | 4000 | 5000 | 5500 | 7000 |
| Minimum Air Flow Rate m³/hr | 800 | 1200 | 1600 | 2200 | 2400 | 2800 |
| Pressure Drop of Air Through Evaporator (Pa) | 150 | 150 | 165 | 250 | 250 | 350 |
| Air Connection IN / OUT (mm) | 200 | 250 | ||||
| Air Temperature IN / OUT °C | 40 / 15 | 40 / 15 | 40 / 10 | 40 / 10 | 40 / 15 | 40 / 15 |
| Relative Humidity % | ||||||
| Electrical Power Supply | 415V, 50 Hz, 3 phase | |||||
| Control Voltage | 24V DC | |||||
| Total Connected Load KW | 13.53 | 15.27 | 23.06 | 26.9 | 28.46 | 31.96 |
| Air Cooled Air Chiller Require Fresh Air Suction on Condenser side and hot exhaust on top of the chiller | ||||||
| Main Dimensions (mm) | ||||||
| W x D x H (mm) | 1150 x 1640 x 2210 | 1610 x 1960 x 2310 | 2350 x 2550 x 2350 | |||
| Weight (Kg.) | 800 | 950 | 1300 | 1550 | ||
| Color | Gray and Off White | |||||
Yes, however, standard models can be less efficient at ambient temperatures above 35°C. In the case of high-temperature areas, high-ambient or tropicalized chillers that have larger condensers and increased airflow are suggested to ensure the reliable cooling effect.
The amount of power consumed depends on the COP (Coefficient of Performance) of the chiller or its EER ( Energy Efficiency Ratio ). Ambient temperature, part-load operation, type of compressor and use of variable speed drives (VSDs) are issues that have a great impact on the costs of energy. More efficient models lead to the reduction of long-term operating costs.
Proper sizing is essential to make sure that it operates properly and is not short-cycling. Calculation of the chiller capacity should be done following the process heat load, ambient conditions, and working hours. Most industrial applications choose a unit that is 10 to 20% larger than the calculated load to allow for controlling peak summer and expansion in the capacity.
Instead of cooling towers and water, the Air-cooled chillers reject heat using ambient air and condenser fans. They are less complex to install and maintain. Water-cooled chillers operate with cooling towers and water circuits and are less efficient at higher capacity than water-cooled chillers, but less expensive to install and much more expensive to maintain as they use water.
Normal reasons are dirty condenser coils or air filters, leakage of refrigerant, poor airflow, improper temperature settings, or a process heat load that is not within the rated capacity of the chiller. These problems can be prevented through regular preventive maintenance.
The level of noise is dependent on the type and the size of the compressor. Smaller to medium-sized chillers with scroll compressors normally run at 60-65 dB, and larger industrial chillers with screw compressors can produce more noise. Where necessary, there are low-noise designs and acoustic enclosures.
We carry a specified warranty and effective after sales services to all goods provided by us. Our warranty and service system will be aimed at long-term performance, reliability in terms of work, and peace of mind of our clients, both domestic and international.
Every product has a standard warranty of manufacturing defects dating back to the dispatch date or the date of installation, as existing. The warranty includes the defects to the quality of material and workmanship in the normal operation condition.
There are various warranty terms based on the product category, model, application and environment of use. Specifics on warranty period and coverage are provided in detail during the confirmation of orders or issue of invoice.
Warranty is not applicable on damages caused by:
Our technical support provides our clients with instructions on how to install, answer technical questions as well as basic troubleshooting. Depending on where the project is located, support is accomplished by providing documentation, remote assistance or by organizing services with service partners.
We assist both domestic and foreign clients with well-organized contact and export documentation. In the case of international customers, technical support and service management are offered remotely to have a comfortable functioning and prompt problem resolution.
There is a process in which service requests are processed. When we get a support request, we examine the problem and determine the warranty eligibility and suggest a remedy. The response timelines can be different depending on the product, location and availability of the components.
The above warranty and support terms are the standard policy which we use in our whole product line. Particular product-level warranty information might vary and are provided independently when taking orders.
This Warranty & Support section represents our standard company-wide policy and is consistently applied across our complete product range. The content is intentionally displayed on multiple product pages to communicate uniform warranty coverage, service terms, and support procedures.
While the core policy remains the same, actual warranty duration, coverage scope, and service conditions may vary by product model, application, and operating environment. Product-specific warranty details are shared separately at the time of order confirmation or documentation.