Air Cooled Screw Chiller is powerful and effective cooling devices that are commonly applied in industries and commercial practices in Afghanistan. These chillers are designed using a developed screw compressor technology, which provides stable performance and long service life even in the 24/7 workload conditions.
Pharmaceutical and large-scale HVAC industries use such chillers due to their ability to maintain accurate temperatures and constant operation when ambient conditions are high. They can be installed within a very short time; their construction is strong and the noise levels are low. This is why they can be used in any demanding industrial environment.
The prominent Air Cooled Screw Chiller Manufacturers in Afghanistan are working towards ISO-certified products, highly developed research and development and customised solutions to suit the various capacity needs. As reputed Air Cooled Screw Chiller Exporters in Afghanistan, we offer the world the globally recognisable systems, and pending international standards in quality & safety guarantee reliable cooling options on the global front.
Aquatech Plus has already become a reputable provider of industrial cooling technology, and in this case, they are proposing high-performance Air Cooled Screw Chiller in Afghanistan as part of various B2B applications. Our years of experience in the industry make us design and supply the industry with robust, energy-efficient and reliable screw chillers that are capable of sustaining ongoing industrial processes.
We have a presence among customers in India. In case you are looking forward to finding reliable Air Cooled Screw Chiller Manufactures in Afghanistan, Aquatech Plus is well equipped and willing to offer you high-quality chillers accompanied by professional technical support and timely delivery.
All air cooled screw chillers at Aquatech Plus are designed and produced in a dust-free environment under a tight ISO 9001 certified quality management system. Our seasoned R&D division is aimed at performance optimization, power efficiency and reliability of operation.
The principle of the working of an Air Cooled Screw Chiller is that of a high-efficiency screw compressor used to squeeze refrigerant to remove heat in chilled water. The heat is directly removed to the surrounding air by air-cooled condensers, and hence, no cooling towers are required.
This design provides the following benefits:
These benefits make the Air-cooled industrial chiller very popular with heavy-duty industrial applications of cooling.
Aquatech Plus produces a complete set of screw type chillers to suit different industrial capacities. Our standard and customized models include the commonly used 50-ton air cooled screw chiller which is used in medium and large-sized production plants.
These advantages will make us a reliable option among Air Cooled Screw Chiller Dealers in Afghanistan.
A number of industrial customers contact us to know the Air cooled Screw Chiller Price in Afghanistan. Pricing at Aquatech Plus is also transparent and competitive depending on cooling capacity, application requirements, and system configuration. We focus on providing a long-term value, efficiency and low-cost of the lifecycle and therefore our chillers are affordable investment to the B2B customers.
All the heavy-duty cooling systems come with a regular 12 months warranty with opportunity to be extended to 5 years. We have a fast technical support whereby any manufacturing related problems are addressed within the warranty period
Moreover, Aquatech Plus provides spare parts that are authentic including:
This combined service will place us among the reliable Air Cooled Screw Chillers Suppliers in Afghanistan as well.
Aquatech Plus is also a reputable Air Cooled Screw Chiller Exporters in Afghanistan, offering export-ready chillers to the international market. Our products are produced based on the ISO, CE and RoHS standards so that the quality and the performance of the products are similar irrespective of the climatic conditions.
In the exporting process, we will ensure:
Our air screw chillers have wide application in:
Although we are based in Gujarat, we are attentively serving industrial clients in Afghanistan, such as Kabul and major regional trade zones, with proper coordination and supply timely and reliable after sales services.
Aquatech Plus would be your partner to count on in case you are seeking an efficient Air Cooled Screw Chiller in Afghanistan supported by engineering knowledge, good production and professional services. We will be delighted to assist you in product selection and customization as well as technical support concerning your industry needs.
Call Aquatech Plus today and receive professional advice and pricing of air cooled screw chiller systems.
| Item | Unit | Model | |||||||||||
|---|---|---|---|---|---|---|---|---|---|---|---|---|---|
| FCAS-80ASH | FCAS-110ASH | FCAS-140ASH | FCAS-160ASH | FCAS-190ASH | FCAS-210ASH | FCAS-250ASH | FCAS-290ASH | FCAS-310ASH | FCAS-340ASH | FCAS-400ASH | FCAS-430ASH | ||
| Cooling Capacity | |||||||||||||
| Cooling Capacity | kW | 80 | 110 | 143 | 157 | 191 | 210 | 247 | 285 | 310 | 340 | 405 | 430 |
| kcal/h | 68800 | 94600 | 122980 | 135020 | 164260 | 180600 | 212420 | 245100 | 266600 | 292400 | 348300 | 369800 | |
| Electrical | |||||||||||||
| Input Power | kW | 32.5 | 43.6 | 54.7 | 59.7 | 73.6 | 79.6 | 88.2 | 101.2 | 112.8 | 123.8 | 145 | 155 |
| Max Current | A | 57 | 75 | 95 | 103 | 125 | 135 | 151 | 173 | 191 | 211 | 246 | 263 |
| Power Source | 3PH~380V / 415V / 480V ~50Hz / 60Hz (3PH~200V / 220V ~50Hz / 60Hz) | ||||||||||||
| Refrigerant | |||||||||||||
| Type | R22 (R134a / R407C / R404A) | ||||||||||||
| Charge | kg | 21 | 28 | 35 | 42 | 49 | 56 | 63 | 70 | 77 | 84 | 98 | 112 |
| Control | Thermostatic Expansion Valve | ||||||||||||
| Compressor | |||||||||||||
| Type | Semi-hermetic Screw | ||||||||||||
| Power | kW | 30 | 40 | 50 | 55 | 67 | 73 | 82 | 95 | 104 | 115 | 134 | 142 |
| Start Mode | Y-Δ | ||||||||||||
| Capacity Control | % | 0-33-66-100 | 0-25-50-75-100 | ||||||||||
| Evaporator | |||||||||||||
| Type | Shell & Tube (SS Plate Heat Exchanger) | ||||||||||||
| Chilled Water | m³/h | 13.8 | 18.9 | 24.6 | 27 | 32.8 | 36.1 | 42.5 | 49 | 53.3 | 58.4 | 70 | 74 |
| Water Pressure | kPa | 32 | 32 | 35 | 38 | 42 | 42 | 45 | 43 | 43 | 43 | 41 | 43 |
| Pipe Connection | inch | 3" | 3" | 3" | 4" | 4" | 4" | 4" | 4" | 5" | 5" | 6" | 6" |
| Condenser | |||||||||||||
| Type | Air-cooled, high-efficiency finned copper tube | ||||||||||||
| Fan | |||||||||||||
| Type | Big volume & low noise axial fan | ||||||||||||
| Power | kW | 0.42×6 | 0.6×6 | 0.78×6 | 0.78×6 | 1.1×6 | 1.1×6 | 0.78×8 | 0.78×8 | 1.1×8 | 1.1×8 | 1.1×10 | 1.1×12 |
| Air Volume | m³/h | 30000 | 40000 | 50000 | 60000 | 70000 | 80000 | 90000 | 100000 | 110000 | 116000 | 145000 | 165000 |
| Safety Protection Devices | |||||||||||||
| Inner thermostat for compressor motor, unit overload relay, high & low pressure switch, freeze protection thermostat, reverse phase protection relay, discharge gas thermostat, flow switch. | |||||||||||||
| Dimensions & Weight | |||||||||||||
| Length | mm | 2200 | 2350 | 2600 | 2600 | 2650 | 2650 | 3400 | 3400 | 3800 | 3800 | 4800 | 5800 |
| Width | mm | 1150 | 1350 | 1500 | 1500 | 1900 | 1900 | 1700 | 1700 | 1900 | 1900 | 1900 | 1900 |
| Height | mm | 1980 | 2000 | 2100 | 2100 | 2200 | 2200 | 2200 | 2200 | 2200 | 2200 | 2200 | 2200 |
| Net Weight | kg | 1100 | 1300 | 1600 | 1900 | 2200 | 2350 | 2550 | 2800 | 2850 | 2950 | 3200 | 3550 |
| Running Weight | kg | 1300 | 1500 | 1840 | 2200 | 2530 | 2700 | 2950 | 3250 | 3350 | 3560 | 3650 | 3950 |
| Item | Unit | Model | |||||||||||
|---|---|---|---|---|---|---|---|---|---|---|---|---|---|
| FCAS-160ADH | FCAS-220ADH | FCAS-285ADH | FCAS-315ADH | FCAS-380ADH | FCAS-420ADH | FCAS-495ADH | FCAS-570ADH | FCAS-620ADH | FCAS-680ADH | FCAS-810ADH | FCAS-860ADH | ||
| Cooling Capacity | |||||||||||||
| Cooling Capacity | kW | 160 | 220 | 286 | 314 | 382 | 420 | 494 | 570 | 620 | 680 | 810 | 860 |
| kcal/h | 137600 | 189200 | 245960 | 270040 | 328520 | 361200 | 424840 | 490200 | 533200 | 584800 | 696600 | 739600 | |
| Electrical | |||||||||||||
| Input Power | kW | 64.7 | 86.6 | 106.2 | 118.8 | 145 | 159.2 | 177.2 | 207.6 | 225.6 | 247.6 | 290 | 310.4 |
| Max Current | A | 114 | 149 | 185 | 205 | 250 | 275 | 308 | 358 | 388 | 428 | 500 | 533 |
| Power Source | 3PH~380V / 415V / 480V ~50Hz / 60Hz (3PH~200V / 220V ~50Hz / 60Hz) | ||||||||||||
| Refrigerant | |||||||||||||
| Type | R22 (R134a / R407C / R404A) | ||||||||||||
| Charge | kg | 21×2 | 28×2 | 35×2 | 42×2 | 49×2 | 56×2 | 63×2 | 70×2 | 77×2 | 84×2 | 98×2 | 112×2 |
| Control | Thermostatic Expansion Valve | ||||||||||||
| Compressor | |||||||||||||
| Type | Semi-Hermetic Screw | ||||||||||||
| Power | kW | 30×2 | 40×2 | 50×2 | 55×2 | 67×2 | 73×2 | 82×2 | 95×2 | 104×2 | 115×2 | 134×2 | 142×2 |
| Start Mode | Y-Δ | ||||||||||||
| Capacity Control | % | 0-33-66-100 | 0-25-50-75-100 | ||||||||||
| Evaporator | |||||||||||||
| Type | Shell and Tube (SS Plate Heat Exchanger) | ||||||||||||
| Chilled Water | m³/h | 27.5 | 37.8 | 49.1 | 54 | 65.7 | 72.2 | 85 | 98 | 106.6 | 117 | 139.3 | 147.9 |
| Water Pressure | kPa | 32 | 32 | 35 | 38 | 42 | 42 | 45 | 43 | 43 | 43 | 41 | 43 |
| Pipe Connection | inch | 4" | 4" | 4" | 5" | 6" | 6" | 6" | 6" | 8" | 8" | 8" | 10" |
| Condenser & Fan | |||||||||||||
| Condenser Type | Air-cooled, high-efficiency finned copper tube | ||||||||||||
| Fan Type | Big volume & low noise axial fan | ||||||||||||
| Fan Power | kW | 0.78×6 | 1.16 | 0.78×8 | 1.1×8 | 1.1×10 | 1.1×12 | 1.1×12 | 1.1×16 | 1.1×16 | 1.1×16 | 1.1×20 | 1.1×24 |
| Air Volume | m³/h | 60000 | 80000 | 100000 | 116000 | 145000 | 165000 | 180000 | 205000 | 225000 | 242000 | 285000 | 325000 |
| Safety Protection | |||||||||||||
| Compressor inner protection, over current protection, high/low pressure protection, over temperature protection, flow rate protection, phase sequence/phase missing protection, low level coolant protection, anti-freezing protection, exhaust overheat protection. | |||||||||||||
| Dimensions & Weight | |||||||||||||
| Length | mm | 2600 | 2650 | 3400 | 3800 | 4800 | 5800 | 5800 | 7800 | 7800 | 8000 | 9800 | 11600 |
| Width | mm | 1500 | 1900 | 1700 | 1900 | 1900 | 1900 | 2200 | 2000 | 2200 | 2200 | 2200 | 2200 |
| Height | mm | 2100 | 2200 | 2200 | 2200 | 2200 | 2200 | 2300 | 2250 | 2250 | 2300 | 2350 | 2350 |
| Net Weight | kg | 2050 | 2520 | 2980 | 3180 | 3420 | 3730 | 3950 | 4330 | 4650 | 4930 | 5450 | 5850 |
| Running Weight | kg | 2360 | 2870 | 3420 | 3690 | 3780 | 4180 | 4380 | 4650 | 4920 | 5360 | 5830 | 6530 |
The performance of chillers depends on how hot (or ambient) the surroundings (or environment) are. Higher ambient temperatures cause chillers to dissipate (or remove) heat inefficiently (or poorly). The operational efficiency improves when the ambient temperature surrounding the operational chillers exceeds certain higher levels. Even in air-cooled chillers that have extreme temperature conditions and are well parameterized, operational efficiency can be close to optimal. This advantage is due to no obstruction of condenser coils, proper system size, and good airflow design.
There has to be adequate airflow in the location to install screw air chillers. The underlying surface should be firm, stable, and level. There is also the need for sufficient air flow around the screw air chillers in the turbine (or cooling) coils. The goal is to prevent the screw air chillers from degrading in performance.
In order to ensure that the system operates in a reliable and sustainable manner and avoid any damage to the system, built-in operational safety measures address system overheating, extreme pressure and temperature, and other system cycle concerns. Furthermore, to ensure safety from phase loss, the system also has the capability of being powered down to avoid overheating.
These chillers are widely used in factories, malls, hospitals, data centres, and process industries where water availability is limited and outdoor installation space is available.
The screw compressor adjusts its capacity smoothly, allowing the chiller to match cooling demand efficiently, reduce power consumption, and maintain stable chilled water temperatures.
Air cooled screw chillers offer easy installation, no cooling tower requirement, lower water usage, and reliable performance for medium to large industrial and commercial cooling applications.
We carry a specified warranty and effective after sales services to all goods provided by us. Our warranty and service system will be aimed at long-term performance, reliability in terms of work, and peace of mind of our clients, both domestic and international.
Every product has a standard warranty of manufacturing defects dating back to the dispatch date or the date of installation, as existing. The warranty includes the defects to the quality of material and workmanship in the normal operation condition.
There are various warranty terms based on the product category, model, application and environment of use. Specifics on warranty period and coverage are provided in detail during the confirmation of orders or issue of invoice.
Warranty is not applicable on damages caused by:
Our technical support provides our clients with instructions on how to install, answer technical questions as well as basic troubleshooting. Depending on where the project is located, support is accomplished by providing documentation, remote assistance or by organizing services with service partners.
We assist both domestic and foreign clients with well-organized contact and export documentation. In the case of international customers, technical support and service management are offered remotely to have a comfortable functioning and prompt problem resolution.
There is a process in which service requests are processed. When we get a support request, we examine the problem and determine the warranty eligibility and suggest a remedy. The response timelines can be different depending on the product, location and availability of the components.
The above warranty and support terms are the standard policy which we use in our whole product line. Particular product-level warranty information might vary and are provided independently when taking orders.
This Warranty & Support section represents our standard company-wide policy and is consistently applied across our complete product range. The content is intentionally displayed on multiple product pages to communicate uniform warranty coverage, service terms, and support procedures.
While the core policy remains the same, actual warranty duration, coverage scope, and service conditions may vary by product model, application, and operating environment. Product-specific warranty details are shared separately at the time of order confirmation or documentation.